Initial Assessment and Detailed Foundation Design for Upgrades.
This project included an initial assessment and detailed foundation design for upgrades to an existing factory complex including building additions and a 40 m tall chimney stack.
The site is made complex by both significant liquefaction and static settlement risk. HD Geo managed the project including overseeing and reviewing the initial site investigation, working with the structural engineering team to provide foundation options, detailed design of piled foundations, construction observation, and review of pile integrity testing for CFA piles.